Apr 2020 : Coupler performance tests at elevated temperatures




The Imperial College London tested Dextra Bartec/Fortec and Griptec couplers at elevated temperatures to evaluate how the couplers would perform in case of a fire.


Highlights of the test include:

  • The findings indicate that current codified rules can be used for assessing the strength and stiffness properties of both non-spliced rebar and rebar connected with Bartec/Fortec or Griptec couplers.
  • At temperatures below 400°C the ultimate tensile strength and stiffness of Bartec/Fortec and Griptec splices, as well as un-spliced rebar is not significantly affected.
  • When tensile tested at temperatures below 500°C, failure still generally occurred in the rebar outside of the Bartec/Fortec or Griptec coupler region.

  • Please read full article below:





    Dextra Bartec/Fortec and Griptec rebar couplers at elevated temperatures



    Dextra have recently collaborated with Imperial College London to investigate the performance of rebar couplers at elevated temperatures, simulating temperatures which could occur in rebar due to fire, both before and after concrete spalling.


    Standard 16mm and 20mm Bartec/Fortec and Griptec couplers were used, as well as non-spliced reinforcement and tests conducted at ambient, elevated steady state and transient elevated temperatures.


    testing machine

    schematic representation of the testing arrangement



    a) testing machine, b) schematic representation of the testing arrangement



    Codified procedures for the fire design of reinforced concrete structures typically give prescriptive recommendations for rebar/coupler cover with the aim of protecting the reinforcement from reaching temperatures above a critical value of around 500°C.


    The test results show that:

  • For both spliced and un-spliced specimens there is a gradual decrease in yield strength as temperature increases.
  • At temperatures below 400°C the ultimate tensile strength and stiffness of the spliced and un-spliced specimens is not significantly affected.
  • When tensile tested at temperatures below 500°C, failure still generally occurred in the rebar outside of the coupler region.

  • The findings also indicate that current codified rules can be used for assessing the strength and stiffness properties of both non-spliced rebar and rebar connected with Bartec/Fortec or Griptec couplers.


    However, the code assumptions regarding the ultimate strain characteristics at elevated temperatures were found to be unrealistic for hot rolled rebar, as well as rebar connected by couplers.



    Need more information about our couplers?


    Discover our coupler range




    References

    Bompa, D. V., & Elghazouli, A. Y. (2019). Elevated temperature characteristics of steel reinforcement incorporating threaded mechanical couplers. Fire Safety Journal, 104, 8–21. https://doi.org/10.1016/j.firesaf.2018.12.006



    About Dextra

    Operating since 1983, Dextra Group is a manufacturing, freight forwarding and trading company specialized in supplying the construction and industrial sectors. We have activities in more than 55 countries through our network of affliates and partners.

    The world leading manufacturer of rebar mechanical splices, we also engineer and produce innovative architectural and geotechnical solutions in high performance steel and FRP composite materials.

    Learn more

    Vision & Mission

    To be a global leader in engineering, manufacturing and delivery of high value added quality products and services for the construction industry.

    Learn more

    Managing Team

    From day one, Dextra has self-managed its growth as a private equity Group, still fully owned by its founders and managers.

    Learn more

    History

    Dextra Group has developed through a long history, during which it encouraged those with an entrepreneurial spirit and constantly strived towards innovation and growth, leading to diversification. Our three main activities are manufacturing, trading and project forwarding, all within the construction and industrial sectors.

    Learn more

    Working at Dextra

    Dextra Group, funded in 1983, is a 900-people strong organization operating within the construction, building material, industrial & forwarding sectors.

    With multiple teams on all continents collaborating on a daily basis, Dextra makes a point to build a strong inclusive multicultural work environment mixing people of various nationality and promoting gender equality in the workplace.

    Learn more

    Don't have an account yet? Register Now!
    Equipment Spare Part Manual Log in

    Sign in to your account